Skip to Main Content (Press Enter)

Logo UNIRC
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Attività
  • Competenze
  • Attrezzature

UNI-FIND
Logo UNIRC

|

UNI-FIND

unirc.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Attività
  • Competenze
  • Attrezzature
  1. Pubblicazioni

Single-crystal diamond MIS diode for deep UV detection

Articolo
Data di Pubblicazione:
2010
Citazione:
Single-crystal diamond MIS diode for deep UV detection / Alfieri, D., Almaviva, S., De Sio, A., Donato, M.G., Faggio, G., Giannini, A., Morgante, S., Pace, E., Scuderi, S., Tripodi, P., Messina, G., Santangelo, S.. - In: RADIATION EFFECTS AND DEFECTS IN SOLIDS. - ISSN 1042-0150. - 165:6-10(2010), pp. 737-745. [10.1080/10420151003729870]
Abstract:
Due to its exceptional physical properties, synthetic diamond is an ideal material for the realization of UV and X-ray detectors to be used for the characterization of laser-generated plasmas. Diamond detectors are able to operate at high temperatures and in the presence of high fluxes of ionizing radiation, where traditional silicon-based detectors usually fail. In this paper, we report on Raman and electro-optical characterization of a structure consisting of intrinsic diamond/boron-doped diamond homoepitaxially grown by chemical vapor deposition onto a commercial high pressure high temperature Ib-type diamond substrate using a 1% CH4/H2 gas mixture. A metal-insulator-semiconductor (MIS) diode was obtained by thermally evaporating an aluminum contact on the growth surface of the intrinsic layer. The detection capability of this device operating in transverse configuration was measured in the deep UV spectral range. The device sensitivity has been estimated at different biasing voltages and at two wavelengths having different penetration depths into the material. The device was also tested at zero biasing voltage (photovoltaic mode operation), showing quite a good photoresponse. These results suggest that MIS structures based on high-quality homoepitaxial diamonds may be successfully utilized for photodetection even at zero bias.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
Raman spectroscopy, ; Single-crystal CVD diamond, ; UV detectors,; Schottky diodes,
Elenco autori:
Alfieri, D.; Almaviva, S.; De Sio, A.; Donato, M. G.; Faggio, Giuliana; Giannini, A.; Morgante, S.; Pace, E.; Scuderi, S.; Tripodi, P.; Messina, Giacomo; Santangelo, Saveria
Autori di Ateneo:
FAGGIO GIULIANA
MESSINA Giacomo
SANTANGELO Saveria
Link alla scheda completa:
https://iris.unirc.it/handle/20.500.12318/928
Pubblicato in:
RADIATION EFFECTS AND DEFECTS IN SOLIDS
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.10.0.0