Design of Square Substrate Integrated Waveguide Cavity Resonators: Compensation of Modelling Errors by Support Vector Regression Machines
Articolo
Data di Pubblicazione:
2012
Citazione:
Design of Square Substrate Integrated Waveguide Cavity Resonators: Compensation of Modelling Errors by Support Vector Regression Machines / Angiulli, G.. - In: AMERICAN JOURNAL OF APPLIED SCIENCES. - ISSN 1546-9239. - 9:11(2012), pp. 1872-1875.
Abstract:
The design of Substrate Integrated Waveguide (SIW) resonators is usually a cumbersome process, especially due to the length âtrial and errorâ procedure involved in this task. In this study Support Vector Regression Machines (SVRMs) are employed to compensate the modeling errors associated to the design of SIW rectangular cavity resonators. To validate the proposed approach, we have compared the design outputs provided by our method with the results provided by commercial full wave software. The comparison between our predictions and the full wave simulations validate the effectiveness of the proposed approach.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
Substrate Integrated Waveguide (SIW); Support Vector Regression Machines
Elenco autori:
Angiulli, Giovanni
Link alla scheda completa:
Pubblicato in: