Skip to Main Content (Press Enter)

Logo UNIRC
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Attività
  • Competenze

UNI-FIND
Logo UNIRC

|

UNI-FIND

unirc.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Attività
  • Competenze
  1. Pubblicazioni

Efficient Attentive U-Net for Fault Diagnosis and Predictive Maintenance of Photovoltaic Panels Through Infrared Thermography

Articolo
Data di Pubblicazione:
2025
Citazione:
Efficient Attentive U-Net for Fault Diagnosis and Predictive Maintenance of Photovoltaic Panels Through Infrared Thermography / Pratticò, D., Laganà, F., Versaci, M., Franković, D., Jakoplić, A., La Foresta, F.. - In: ENERGIES. - ISSN 1996-1073. - 18:24(2025). [10.3390/en18246472]
Abstract:
Photovoltaic (PV) systems represent one of the pillars of the global energy transition, yet their reliability and long-term efficiency are constantly threatened by hidden defects and progressive degradation. Early and precise identification of such anomalies is essential for ensuring safety, enhancing performance, and facilitating predictive maintenance plans. Infrared thermography (IRT) is a non-invasive and cost-effective technique for the inspection of PV modules. This study proposes an efficient attentive U-Net architecture for the semantic segmentation of thermographic images, aimed at supporting predictive maintenance and power loss assessment. The model integrates squeeze-and-excitation (SE) and attention gate (AG) modules with atrous spatial pyramid pooling (ASPP), achieving an optimal balance between accuracy and computational complexity. A comprehensive ablation study, including input resolution and module combinations, was conducted on a dataset of 500 thermograms annotated into six defect classes. The proposed configuration (256 × 256 input) achieved a mean Intersection over Union (mIoU) of 81.4% and a macro-F1 score of 87.5%, outperforming U-Net and DeepLabv3+ by over 4 percentage points, with only 5.24 M parameters and an inference time of 118.6 ms per image. These results confirm the suitability of the framework for energy-oriented fault diagnosis and near real-time monitoring of photovoltaic plants.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
CNN; deep learning; energy yield; fault diagnosis; infrared thermography; photovoltaic systems; predictive maintenance; U-Net
Elenco autori:
Pratticò, Danilo; Laganà, Filippo; Versaci, Mario; Franković, Dubravko; Jakoplić, Alen; La Foresta, Fabio
Autori di Ateneo:
LA FORESTA Fabio
VERSACI Mario
Link alla scheda completa:
https://iris.unirc.it/handle/20.500.12318/164368
Pubblicato in:
ENERGIES
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.6.0.0